NI MAX software setup¶
NI MAX software acts as an interface between Hardware Setup and OM software. Here is where we set acquisition parameters for equipment test. Following are the instructions:
- Double click on NIMAX icon on Desktop or do it from start menu. Following window appears.
- Double click on Data Neighborhood in the window to the left shows NI-DAQms Tasks—> Create a new task with the mouse right click—> Add Acquire Signals, then Analog Input—> Choose Voltage—> under Supported Physical Channels use Ctrl or Shift to select the Hammer and the Accelerometer connected to NI Board (in the case of figure below, it was ai3 and ai7).
- Now, its time to set acquisition parameters for both the sensors and test them. Once MyVoltageTask window opens—> go to configuration—> Voltage_0(Accelerometer)
- Signal Input Range—> Max: 10, Min: -10, Units: Volts
- Terminal Configuration—> Differential
- Custom Scaling—> No Scale
- Acquisition Mode—> Continuous Samples
- Samples to Read—> 800
- Rate(Hz)—> 2000
- Leave other options to default
- Click on Save, to save this configuration
Note
Similar configuration may be used for Voltage_1(Hammer).
- Then, to test the Hammer—> Click on Run—> Gently strike the table with the hammer, spike should occur in the graph as shown in the following figure
- Similarly, to test the Accelerometer—> Click on Run—> Gently tap the beam with your finger—> Inspect the Accelerometer response in the plot window, oscillations should occur at the time points as shown in figure below:
Note
It is important to save the configuration as you change them.
That ends NIMAX software Setup